This is for a box of 40pcs.These are new Phoenix PTIO-IN 2,5/4-PE OG 3244481 that we had purchased for production of our equipment and then we decided to go with a different terminal block system.
These cost .54ea a total of 1 from Mouser Electronics.
Thank you for looking!
Specs from the Manufacturer:
Sensor/actuator terminal block, with protective conductor function, nom. voltage: 250 V, nominal current: 20 A, connection method: Push-in connection, number of connections: 3, cross section:0.2 mm² - 4 mm², AWG: 24 - 12, width: 7 mm, color: orange, mounting type: NS 35/7,5, NS 35/15
General
Number of levels
4
Number of connections
3
Potentials
3
Nominal cross section
2.5 mm²
Color
orange
Insulating material
PA
Flammability rating according to UL 94
V0
Maximum load current
20 A
Rated surge voltage
4 kV
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Maximum power dissipation for nominal condition
0.77 W (the value is multiplied when connecting multiple levels)
Maximum load current
20 A
Nominal current I
N
20 A
Nominal voltage U
N
250 V
Open side panel
Yes
Shock protection test specification
DIN EN 50274 (VDE 0660-514):2002-11
Back of the hand protection
guaranteed
Finger protection
guaranteed
Result of surge voltage test
Test passed
Surge voltage test setpoint
4.8 kV
Result of power-frequency withstand voltage test
Test passed
Power frequency withstand voltage setpoint
1.5 kV
Result of the test for mechanical stability of terminal points (5 x conductor connection)
Test passed
Result of bending test
Test passed
Bending test rotation speed
10 rpm
Bending test turns
135
Bending test conductor cross section/weight
0.2 mm² / 0.2 kg
2.5 mm² / 0.7 kg
4 mm² / 0.9 kg
Tensile test result
Test passed
Conductor cross section tensile test
0.2 mm²
Tractive force setpoint
10 N
Conductor cross section tensile test
2.5 mm²
Tractive force setpoint
50 N
Conductor cross section tensile test
4 mm²
Tractive force setpoint
60 N
Result of tight fit on support
Test passed
Tight fit on carrier
NS 35
Setpoint
1 N
Result of voltage-drop test
Test passed
Result of temperature-rise test
Test passed
Short circuit stability result
Test passed
Conductor cross section short circuit testing
4 mm²
Short-time current
0.36 kA
Conductor cross section short circuit testing
4 mm²
Short-time current
0.48 kA
Result of thermal test
Test passed
Ageing test for screwless modular terminal block temperature cycles
192
Proof of thermal characteristics (needle flame) effective duration
30 s
Result of aging test
Test passed
Oscillation, broadband noise test result
Test passed
Test specification, oscillation, broadband noise
DIN EN 50155 (VDE 0115-200):2008-03
Test spectrum
Service life test category 2, bogie-mounted
Test frequency
f
1
= 5 Hz to f
2
= 250 Hz
ASD level
6.12 (m/s
2
)
2
/Hz
Acceleration
3.12 g
Test duration per axis
5 h
Test directions
X-, Y- and Z-axis
Shock test result
Test passed
Test specification, shock test
DIN EN 50155 (VDE 0115-200):2008-03
Shock form
Half-sine
Acceleration
30g
Shock duration
18 ms
Number of shocks per direction
3
Test directions
X-, Y- and Z-axis (pos. and neg.)
Relative insulation material temperature index (Elec., UL 746 B)
130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
130 °C
Static insulating material application in cold
-60 °C
Back to top
Dimensions
Width
7 mm
End cover width
2.2 mm
Length
90.8 mm
Height NS 35/7,5
41.5 mm
Height NS 35/15
49 mm
Back to top
Connection data
Note
Please observe the current carrying capacity of the DIN rails.
Connection method
Push-in connection
Connection in acc. with standard
IEC 60947-7-1/IEC 60947-7-2
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
4 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
12
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Min. AWG conductor cross section, flexible
24
Max. AWG conductor cross section, flexible
14
Conductor cross section flexible, with ferrule without plastic sleeve min.
0.2 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
2.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.
0.2 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
2.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max.
0.5 mm²
Stripping length
8 mm ... 10 mm
Internal cylindrical gage
A3
Back to top
Standards and Regulations
Connection in acc. with standard
IEC 60947-7-1/IEC 60947-7-2
Flammability rating according to UL 94
V0
Back to top
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Back to top
Classifications
eCl@ss
eCl@ss 4.0
27141118
eCl@ss 4.1
27141118
eCl@ss 5.0
27141118
eCl@ss 5.1
27141100
eCl@ss 6.0
27141100
eCl@ss 7.0
27141128
eCl@ss 8.0
27141128
eCl@ss 9.0
27141128
Back to top
ETIM
ETIM 3.0
EC000897
ETIM 4.0
EC000897
ETIM 5.0
EC000900
ETIM 6.0
EC000900
Back to top
UNSPSC
UNSPSC 6.01
30211811
UNSPSC 7.0901
39121410
UNSPSC 11
39121410
UNSPSC 12.01
39121410
UNSPSC 13.2
39121410